All the courses are now available in Broome Location as well.
West Coast First Aid Training

What is Little Anne and Little Junior QCPR Upgrade kit?

  1. Home
  2. CPR
  3. What is Little Anne...
west coast first aid

Little Anne and Little Junior – QCPR upgrade kits


Upgrade your old Little Anne and Little Junior to function with the QCPR App feedback system.

https://www.youtube.com/embed/OdZe3L9DboM


How do Little Anne and Little Junior QCPR work? 


Upgrade Little Anne

All existing Little Anne manikins, manufactured after 08. February 1999, can be upgraded to Little Anne QCPR.

See below to identify if the manikin is too old to be upgraded.

How to install Little Anne QCPR Upgrade Kit?

Item 123-60750 – Little Anne QCPR Upgrade kit

  • Modified Rib Plate with QCPR Sensor
  • Clicker Activator on the Rib plate
  • Ventilation Sticker Guide
  • Ventilation Sticker
  • Reflector for compression
  • Jaw assembly (with flexible valve holder)
  • 2 x AA Battery
  • QCPR Label for manikin
  • QCPR Label for bag


Kits manufactured after 14. February 2020, has a compression reflector made of plastic. It was originally made of foam.

NB: If the manikin’s Chest skin is old and worn out, it is recommended also to purchase a new skin.
Item 123-50650 – QCPR Chest skin, Light
Item 123-50750 – QCPR Chest skin, Dark


Upgrade Little Junior


All existing Little Junior manikins can be upgraded to Little Junior QCPR.

Item 128-60750 – Little Junior QCPR Upgrade kit

  • Modified Rib Plate with QCPR Sensor
  • Clicker Activator on the Rib plate
  • Ventilation Sticker Guide
  • Ventilation Sticker
  • Reflector for compression
  • Compression spring
  • 2 x AA Battery
  • QCPR Label for manikin
  • QCPR Label for bag

NB: If the manikin’s Chest skin is old and worn out, it is recommended also to purchase a new skin.
Item 128-50650 – QCPR Chest skin, Light
Item 128-50750 – QCPR Chest skin, Dark


Is your Little Anne manikin too old to be upgraded?


Manikins manufactured before 1999-02-08, cannot be upgraded.

– Chest skin: The old design has a higher chest than the current skin. The higher amount of empty space between Chest skin and Chest plate obstructs the registration of ventilations.
– Back section: The old design has both attachment pegs for skin placed at the lower position and it cannot support a QCPR Chest skin that requires the left side peg at a higher position & right side peg at the lower position.

Identified by looking at the Chest skin flap and the placement of the hole:

LEFT SIDE: Can be upgraded
RIGHT SIDE: Too old, cannot be upgraded

Additionally…

The very first generation of Little Anne manikins cannot be upgraded:
– The Rib plate is welded together with the Back section, and cannot be replaced with the QCPR Rib plate.
– To verify if the manikin can be upgraded – remove the Chest skin and compare with the picture.